Ipayipi le-Silicone Foley nge-Temperature Probe

Incazelo emfushane:

• Yenziwe ngo-100% wezicucu zezinga lezokwelapha ezingenisiwe ezingenisiwe.
• Ibhaluni elithambile nelinomoya ofanayo lenza ishubhu lihlale kahle esinyeni.
• I-valve enekhodi yokuhlola enemibala yokuhlonza osayizi abahlukene.
• Kuyindlela engcono kakhulu ezigulini ezibucayi zepayipi eligciniwe ukukala izinga lokushisa kwemizimba yazo.
• Ukuzwa izinga lokushisa.


Imininingwane yomkhiqizo

Amathegi womkhiqizo

Isici

Silicone Foley Catheter with Temperature Probe

Ukupakisha: 10 PC / ibhokisi, 200 PC / ibhokisi
Usayizi webhokisi: 52x34x25 cm

Ukusetshenziswa okuhlosiwe

Isetshenziselwa ukwenziwa kwe-catheterization ejwayelekile yomtholampilo noma i-urethral drainage yokuqapha okuqhubekayo kokushisa kwesisu seziguli ngesiqapha.

Ukwakheka kwesakhiwo

Lo mkhiqizo wakhiwa nge-urethral drainage catheter kanye ne-probe yokushisa. I-catheter ye-Urethral drainage iqukethe umzimba we-catheter, ibhaluni (isaka lamanzi), inhloko yomhlahlandlela (ithiphu), isikhombimsebenzisi se-lumenge lumen, ukugcwalisa isikhombimsebenzisi se-lumen, isikhombimsebenzisi sokulinganisa i-lumen interface, i-flushing lumen interface (noma cha), i-flushing lumen plug (noma cha) nomoya valve. Ithuluzi lokushisa liqukethe iprosesa lokushisa (i-chip eshisayo), i-plug interface kanye nokwakheka kwentambo. Ipayipi lezingane (8Fr, 10Fr) lingafaka ucingo oluyisiqondisi (uma uthanda). Umzimba we-catheter, ikhanda lomhlahlandlela (ithiphu), ibhaluni (isaka lamanzi) kanye ne-lumen interface ngayinye yenziwe nge-silicone; valve emoyeni senziwa polycarbonate, ABS plastic kanye polypropylene; ipulaki eshaywayo yenziwa nge-PVC ne-polypropylene; ucingo lwesiqondisi lwenziwe nge-PET plastic kanye ne-probe yokushisa kwenziwa nge-PVC, fiber kanye nezinto zensimbi.

Inkomba yokusebenza

Lo mkhiqizo ufakwe i-thermistor ezwa ukushisa okuyisisekelo kwesinye. Ububanzi bokulinganisa bungu-25 ℃ kuye ku-45 ℃, futhi ukunemba kungu- ± 0.2 ℃. Isikhathi sokulinganisa semizuzwana engu-150 kufanele sisetshenziswe ngaphambi kokulinganisa. Amandla, isixhumi sokuhlukanisa amandla, ukuthembeka kwebhaluni, ukumelana okugoqayo nokugeleza kwezinga lalo mkhiqizo kuzofinyelela izidingo ze-ISO20696: 2018 standard; ukuhlangabezana nezidingo zokuhambisana kwe-electromagnetic ze-IEC60601-1-2: 2004; ukuhlangabezana nezidingo zokuphepha kagesi ze-IEC60601-1: 2015. Lo mkhiqizo uyinyumba futhi awunanzalo yi-ethylene oxide. Inani eliyinsalela le-ethylene oxide kufanele libe ngaphansi kuka-10 μg / g.

Imibhalo / Imininingwane

Ukucaciswa kwegama

Ivolumu yebhaluni

(ml)

Ikhodi yombala yokukhomba

Imibhalo

Ukucaciswa kwesiFulentshi (Fr / Ch)

Igama eliqhamuka ngaphandle lepayipi le-catheter (mm)

i-lumen yesibili, i-lumen yesithathu

8

2.7

3, 5, 3-5

okuluhlaza okwesibhakabhaka okuphaphathekile

10

3.3

3, 5, 10, 3-5, 5-10

mnyama

12

4.0

5, 10, 15, 5-10, 5-15

okumhlophe

14

4.7

5, 10, 15, 20, 30, 5-10, 5-15, 10-20, 10-30, 15-20, 15-30, 20-30

luhlaza okotshani

16

5.3

iwolintshi

I-lumen yesibili, i-lumen yesithathu, ukuphuma kwe-lumen

18

6.0

5, 10, 15, 20, 30, 50, 5-10, 5-15, 10-20, 10-30, 15-20, 15-30, 20-30, 30-50

okubomvu

20

6.7

ophuzi

22

7.3

okunsomi

24

8.0

okuluhlaza okwesibhakabhaka

26

8.7

obomvana

Imiyalo

1. Ukuthambisa: ipayipi kufanele ligcotshiswe ngothambisa wezokwelapha ngaphambi kokufakwa.

2. Ukufaka: faka ipayipi elithanjisiwe emthanjeni uye esinyeni ngokucophelela (umchamo uyakhishwa ngalesi sikhathi), bese ufaka u-3-6cm bese wenza ibhaluni lingene esinyeni ngokuphelele.

3. Amanzi afuthayo: Usebenzisa isirinji engenaliti, faka ibhaluni ngamanzi oyinyumba angahluziwe noma i-10% ye-glycerin solutionque ehlinzekwayo. Ivolumu enconyiwe ongayisebenzisa imakwe kufaneli ye-catheter.

4.Ukulinganisa ithempelesha: uma kunesidingo, xhuma ukuphela kwangaphandle kwesixhumi sesimo sokushisa nesokhethi yesibuko. Ukushisa kweziguli kungabhekwa ngesikhathi sangempela ngemininingwane ekhonjiswe ukuqapha.

5. Susa: Lapho ukhipha ipayipi, okokuqala hlukanisa i-interface yomugqa wokushisa kusuka kumonitha, faka isipontsho esingenalutho ngaphandle kwenaliti ku-valve, namanzi angenamsoco ebhaluni. Lapho umthamo wamanzi esirinji usondele kulowo womjovo, ipayipi lingakhishwa kancane, noma umzimba weshubhu unganqunywa ukuze kususwe ipayipi ngemuva kokudonsa ngokushesha.

6. Ukuhlala: Isikhathi sokuhlala sincike ezidingweni zomtholampilo nasezidingweni zobuhlengikazi, kepha isikhathi esiphezulu sokuhlala ngeke seqe izinsuku ezingama-28.

Ukuphikisana

1. I-urethritis enamandla.
2. I-acute prostatitis.
3. Ukwehluleka kwe-intubation yokuphuka kwe-pelvic nokulimala kwe-urethral.
4. Iziguli zibhekwa njengezingalungile odokotela.

Ukunakwa

1. Lapho uthambisa ipayipi, ungasebenzisi i-lubricant equkethe uwoyela substrate. Isibonelo, ukusebenzisa uwoyela kaphalafini njengesithambisi kuzodala ukuqhuma kwebhaluni.
2. Osayizi abahlukahlukene bama-catheters kufanele bakhethwe ngokweminyaka ngaphambi kokusetshenziswa.
3. Ngaphambi kokusetshenziswa, hlola ukuthi ingabe ipayipi le-catheter limi kahle yini, ukuthi ibhaluni liyavuza yini noma cha, nokuthi ukuncela akuvinjelwe yini. Ngemuva kokuxhuma ipulagi lokuhlola lokushisa nesiqaphi, noma ngabe idatha ekhonjisiwe ayijwayelekile noma cha.
4. Sicela uhlole ngaphambi kokusetshenziswa. Uma noma yimuphi umkhiqizo owodwa (ogcwele) utholakala unezimo ezilandelayo, akuvunyelwe ukusebenzisa:
A) ngaphezu kosuku lokuphelelwa yisikhathi lokuvala inzalo;
B) iphakethe elilodwa lomkhiqizo lilimele noma linezindaba zangaphandle.
5. Abasebenzi bezokwelapha kufanele bathathe izinyathelo ezithambile ngesikhathi sokugubha noma sokuxubha, futhi banakekele kahle isiguli nganoma yisiphi isikhathi ngesikhathi sokufakwa kwe-catheterization ukuze kuvikelwe izingozi.
Inothi elikhethekile: lapho ithubhu lomchamo elihlala ngemuva kwezinsuku eziyi-14, ukuze kugwenywe ishubhu lingashibilika ngenxa yokwehla kwamandla omzimba oyinyumba ebhaluni, abasebenzi bezokwelapha bangafaka amanzi oyinyumba ebhaluni ngasikhathi sinye. Indlela yokusebenza imi kanjena: gcina ishubhu lomchamo lisesimweni esigciniwe, ukhiphe amanzi oyinyumba ngaphandle kwebhaluni ngesirinji, bese ufaka amanzi oyinyumba kubhaluni ngokusho kwamandla okuzisholo.
6. Faka ucingo lomhlahlandlela esikhwameni samanzi se-catheter sezingane njenge-intubation esizayo. Sicela udwebe ucingo lwesiqondisi ngemuva kokutholwa.
7. Lo mkhiqizo unenzalo nge-ethylene oxide futhi unesikhathi esivumelekile seminyaka emithathu kusukela osukwini lokukhiqizwa.
8. Lo mkhiqizo ulahlwa ukuze usetshenziswe emitholampilo, uqhutshwa ngabasebenzi bezokwelapha, futhi ubhujiswe ngemuva kokusetshenziswa.
9. Ngaphandle kokuqinisekisa, kuzogwenywa ukusetshenziswa kwinqubo yokuskena kohlelo lwe-nuclear magnetic resonance ukuvimbela ukuphazamiseka okungahle kuholele ekusebenzeni okungalingani kokushisa kokushisa.
10. Isikhathi sokuvuza sesiguli sizolinganiswa phakathi komhlaba kanye ne-thermistor ku-110% wenani eliphakeme kakhulu lamanani okuhlinzekwa kwenethiwekhi.

Ukufundiswa kweMonitor

1. Kuyaphatheka ukuqapha kwamapharamitha amaningi (imodeli mec-1000) kulo mkhiqizo;
2.i / p: 100-240V-, 50 / 60Hz, 1.1-0.5A.
3. Lo mkhiqizo uhambisana nesistimu yokuqapha izinga lokushisa le-YSI400.

Amathiphu wokuhambisana kwe-Electromagnetic

Lo mkhiqizo kanye nemishini yokuqapha exhunywe kuzothatha izinyathelo ezithile zokuqapha maqondana nokuhambisana kwe-electromagnetic (EMC) futhi kuzofakwa futhi kusetshenziswe ngokuhambisana nemininingwane yokuhambisana ne-electromagnetic ebalulwe kulo myalelo.
Umkhiqizo kufanele usebenzise izintambo ezilandelayo ukuhlangabezana nezidingo zokukhishwa kwe-electromagnetic nokuphikisana nokuphazamiseka:

Ikhebula igama

ubude

Ulayini wamandla (16A)

<3m

2. Ukusetshenziswa kwezesekeli, izinzwa nezintambo ezingaphandle kwebanga elicacisiwe kungakhuphula ukuphuma kwe-electromagnetic kwemishini kanye / noma kwehlise ukuvikeleka kwamandla kagesi kwensimbi.
3. Lo mkhiqizo nedivayisi yokuqapha exhunywe ayikwazi ukusetshenziswa eduze noma ukustakwa namanye amadivayisi. Uma kunesidingo, ukubhekelwa okuseduze nokuqinisekiswa kuzokwenziwa ukuqinisekisa ukusebenza kwayo okujwayelekile ekucushweni okusetshenzisiwe.
4. Lapho i-amplitude yesiginali yokufaka iphansi kunesilinganiso esiphansi esichazwe kuzincazelo zobuchwepheshe, isilinganiso kungenzeka singanembi.
5. Noma ngabe enye impahla ihambisana nezidingo zokuqalisa ze-CISPR, ingadala ukuphazamiseka kulo mshini.
6. Amadivayisi wokuxhumana aphathekayo nawamaselula azothinta ukusebenza kwedivayisi.
7. Amanye amadivayisi aqukethe ukungcola kwe-RF angaphazamisa ifoni (isb. Umakhalekhukhwini, i-PDA, ikhompyutha enokusebenza okungenantambo).

[Umuntu obhalisiwe]