HAIYAN KANGYUAN MEDICAL INSTRUMENT CO., LTD.

I-Suprapubic Silicone Foley Catheter

Incazelo emfushane:

I-Suprapubic Silicone Foley Catheter Open Tipped with Integral Balloon Male Female
Yenziwe nge-silicone ye-medical-garde engenisiwe engu-100%.


Imininingwane Yomkhiqizo

Omaka bomkhiqizo

Isici

I-Suprapubic Silicone Foley Catheter Open Tipped with Integral Balloon Male Female
Yenziwe nge-silicone ye-medical-garde engenisiwe engu-100%.
Lo mkhiqizo ungowe-Class IIB.
Ulayini opaque werediyo kubude bokubukwa kwe-x-ray ye-fot.
Ibhaluni elithambile nelivuthwe ngendlela efanayo lenza ishubhu lihlale kahle ngokumelene nesinye.
Umklamo ovulekile ovulekile, ukwandisa umthamo we-drainage.
I-vavle yokuhlola enemibala enemibala yokuhlonza osayizi abahlukahlukene.
Ubude be-catheter ye-Foley: 400mm.

1

Ukupakisha:10 ama-pcs/ibhokisi, 200 ama-pcs/ibhokisi
Usayizi webhokisi:52x35x25 cm

Isici somkhiqizo

I-"KANGYUAN"I-Urinary Catheters for Single Use (i-Foley) yenziwe ngerabha ye-silicon engenisiwe ngobuchwepheshe obuthuthukisiwe. Umkhiqizo unobuso obushelelezi, ukuvuselela kancane, ivolumu enkulu ye-apocenosis, ibhaluni elithembekile, elisebenziseka kalula, izinhlobo eziningi kanye nokucaciswa kokukhetha.

Ukwakheka kwesakhiwo

Lo mkhiqizo wakhiwe nge-urethral drainage catheter kanye ne-temperature probe. I-Urethral drainage catheter inomzimba we-catheter, ibhaluni (isikhwama samanzi), inhloko yomhlahlandlela (ithiphu), isixhumi esibonakalayo se-lumen ye-drainage, isixhumi esibonakalayo selume, isixhumi esibonakalayo sokulinganisa izinga lokushisa, isixhumi esibonakalayo esishisayo se-lumen (noma cha), ipulaki yelume elishisayo (noma cha) nomoya. i-valve. I-temperature probe iqukethe i-temperature probe (i-thermal chip), isixhumi esibonakalayo sepulaki kanye nokwakheka kwentambo yomhlahlandlela. I-Catheter yezingane(8Fr, 10Fr) ingafaka intambo yomhlahlandlela(uma uthanda). Umzimba we-catheter, inhloko yomhlahlandlela (ithiphu), ibhaluni (isikhwama samanzi) kanye nesixhumi esibonakalayo se-lumen ngasinye zenziwe nge-silicone; i-valve yomoya yenziwe nge-polycarbonate, ipulasitiki ye-ABS ne-polypropylene; ipulaki eshaywayo yenziwe nge-PVC ne-polypropylene; ucingo oluqondisayo lwenziwe ngepulasitiki ye-PET kanye ne-temperature probe yenziwe nge-PVC, i-fiber kanye nensimbi.

Ukusebenza

Umkhiqizo ungasetshenziswa ngokomtholampilo ukuchama nokuchama esinyeni ngokufaka esinyeni somchamo nakuba urethra.

Isiqondiso sokusebenzisa

1. Ukugcotshwa: Gcoba ngokukhululekile ithiphu ne-shaft ye-catheter ngaphambi kokufaka.

2. Faka: Faka ngokucophelela ithiphu le-catheter esinyeni (ngokuvamile kuboniswa ukugeleza komchamo), bese kuba u-3cm ngaphezulu ukuqinisekisa ukuthi ibhaluni nalo lingaphakathi kuso.

3. Amanzi afuthwayo:Usebenzisa isirinji engenanaliti, vuthela ibhaluni ngamanzi acwebile angenalutho noma u-5%,Isixazululo esingu-10% se-glycerin samanzi sinikezwa.Ivolumu enconyiwe okufanele isetshenziswe imakwe kufaneli ye-catheter.

4. Ukukhipha: Ukuze unciphise amandla, nqamula ifaneli yokwehla kwamandla emali ngaphezu kwevalvu, noma usebenzise isirinji ngaphandle kokuphusha inaliti kuvalvu ukuze kube lula ukugeleza kwamanzi.

5. I-catheter yokuhlala: isikhathi sokuhlala siyisidingo somtholampilo kanye nomhlengikazi.

Contraindication

Isimo esingafanele esicatshangelwa udokotela.

Ukuqapha

1. Ungawasebenzisi amafutha noma izinto zokuthambisa ezinesisekelo se-petroleum.
2. Ukucaciswa okuhlukile kwe-catheter ye-urethral kufanele kukhethwe njengeminyaka ehlukene ngaphambi kokusetshenziswa.
3. Lo mkhiqizo ubufakwe inzalo ngegesi ye-ethylene oxide, futhi uyilahle ngemva kokusetshenziswa kanye.
4. Uma ukupakisha konakele, ungasebenzisi.
5. Usayizi kanye nomthamo webhaluni kumakwe kuyunithi yephakethe langaphandle kanye nefaneli ye-catheter.
6. Ucingo oluqondisayo lwe-intubation eyisizayo emhubheni wokudonsa amanzi we-catheter lufakwe ngaphambili ezinganeni.
7. Esetshenziswayo, njengokutholakala kwe-catheter yomchamo, ukuphuma komchamo, ukugeleza kwamanzi okunganele,
Ukushintshwa kwe-catheter kufanele kube imininingwane esebenzayo ngesikhathi.
8. Lo mkhiqizo kufanele usetshenziswe abasebenzi bezokwelapha.

[Isexwayiso]
Umjovo wamanzi oyinyumba akufanele udlule umthamo we-catheter (ml).

[Isitoreji]
Gcina endaweni epholile, emnyama neyomile, izinga lokushisa akufanele libe ngaphezu kuka-40 ℃, ngaphandle kwegesi egqwalayo kanye nomoya omuhle.
[Idethi yokukhiqiza]Bona ilebula yokupakisha yangaphakathi
[Eidethi ye-xpiry]Bona ilebula yokupakisha yangaphakathi
[Umuntu obhalisiwe]
Umkhiqizi: HAIYAN KANGYUAN MEDICAL Instrument CO., LTD


  • Okwedlule:
  • Olandelayo:

  • Imikhiqizo Ehlobene